Contact Us
13, 1st Street, Simplicio Cruz Compound, Barangay San Isidro, Paranaque City
+632 8526-4869 • 8252-1135 • 8252-1136 • 8352-6612 • 8535-5017
+632 8526-4870
Related Products

Soft Starter Assemblies (SSA)

Soft Starter Assemblies (SSA)
Soft Starters help lower the risk of a power surge and damage as it gradually increases in power instead of going full power during startup.







LADN11

LADN11
TeSys D – auxiliary contact block – 1 NO + 1 NC – screw-clamps terminals

WiNtrip MCB & Isolator

WiNtrip MCB & Isolator
RANGE
- Rating: 0.5A ~ 125A, Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
- Rating: 0.5A ~ 63A (DC), Poles: 1P & 2P
Isolator
- Rating: 25A~125A
- Poles: 1P, 2P, 3P & 4P
FEATURES
- Tripping curves: B, C & D
- Breaking Capacity 10kA
- IP 20 degree protection
- Trip Free mechanism with padlocking facility
- Low Power Consumption
- Current limiting design – class 3
- Air Circulation
Contact Us also available on 


LADR2

LADR2
Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 1-30s, front, screw clamp terminals

ATV212HD18M3X

ATV212HD18M3X
18.5Kw/25Hp 200…240VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation